Audiometers
Diagnostic Equipment
Audiometers(20 products)
Hearing assessment devices

Interacoustics CA 100 Pure Tone Audiometer
Interacoustics China
The Interacoustics CA 100 is a precision pure tone audiometer designed for comprehensive hearing threshold assessment. It features a frequency range of 125 Hz to 8000 Hz with octave and half-octave steps, accurate tone generation with less than 3% harmonic distortion, and an intuitive color touchscreen interface. The device supports air conduction and bone conduction testing with dedicated transducer channels, and includes built-in audiometric masking capabilities.
Applications:

Madsen Eclipse Speech Audiometer
Madsen China
The Madsen Eclipse is a dedicated speech audiometer designed for speech recognition threshold testing and speech discrimination score assessment. It features high-fidelity speech reproduction through calibrated speakers and headphones, configurable speech material lists in Mandarin and Cantonese, and automated scoring algorithms. The device supports live speech and recorded speech testing with ambient noise monitoring.
Applications:

Siemens UNIQA Portable Audiometer
Siemens China
The Siemens UNIQA is a compact portable audiometer engineered for mobile hearing assessment in diverse environments. Weighing under 500 grams, it offers full-frequency pure tone audiometry from 125 Hz to 8000 Hz with rechargeable battery operation lasting up to 20 hours. The device features a high-contrast OLED display, intuitive button interface, and automatic test protocols for rapid screening.
Applications:
Oticon Dynamo Screening Audiometer
Oticon China
The Oticon Dynamo is an efficient screening audiometer designed for rapid hearing assessment in high-throughput settings. It features automated pass/refer protocols based on WHO hearing loss grades, one-button test initiation, and instant result printout. The device supports both headset and sound booth configurations with ambient noise level display to ensure test validity.
Applications:

Starkey Aura Clinical Audiometer
Starkey China
The Starkey Aura is a premium clinical audiometer offering comprehensive diagnostic capabilities for audiology professionals. It features a 10.1-inch HD touchscreen, 14 frequency test points from 125 Hz to 12,000 Hz, multi-channel signal routing, and integrated tympanometry module. The device provides advanced masking strategies, SISI, ABLB, and tone decay tests with automated clinical decision support.
Applications:

Phonak Target Pediatric Audiometer
Phonak China
The Phonak Target Pediatric Audiometer is specially designed for hearing assessment of children from newborn to 16 years. It features child-friendly interface with animated visual reinforcement, condition play audiometry modes, and calibrated sound field testing. The device includes age-appropriate test protocols, parental observation questionnaires, and detailed pediatric reporting templates.
Applications:

Interacoustics Eclipse VNG Newborn Hearing Screening System
Interacoustics China
The Interacoustics Eclipse VNG is an advanced newborn hearing screening system combining automated auditory brainstem response (AABR) and otoacoustic emissions (OAE) in a single integrated platform. It features simultaneous bilateral testing, pass/refer algorithms based on international screening guidelines, and seamless NICU integration. The device offers ultra-quiet operation below 30 dB SPL for optimal testing conditions.
Applications:

Madsen Zodiac Tympanometer
Madsen China
The Madsen Zodiac is a high-precision tympanometer for middle ear function assessment. It measures tympanic membrane compliance, ear canal volume, and middle ear pressure across a frequency range of 226 Hz to 1000 Hz. The device features auto-tympanometry with preset protocols, ipsilateral and contralateral reflex testing, and detailed tympanogram classification with automated interpretation.
Applications:

Siemens Sentinel OAE System
Siemens China
The Siemens Sentinel is a comprehensive otoacoustic emissions (OAE) system for cochlear function evaluation. It performs both transient-evoked otoacoustic emissions (TEOAE) and distortion product otoacoustic emissions (DPOAE) measurements with high sensitivity and specificity. The device features automated pass/refer decision making, probe fit verification, and real-time noise monitoring for reliable test results.
Applications:
Oticon NeuroLink ABR System
Oticon China
The Oticon NeuroLink is an advanced auditory brainstem response (ABR) system for objective hearing threshold estimation and auditory pathway evaluation. It features automated ABR wave identification with AI-assisted latency analysis, click and tone burst stimuli, and bone conduction ABR capability. The system includes neonatal-optimized protocols, artifact rejection algorithms, and comprehensive reporting with normative data comparison.
Applications:

Starkey Harmonia Audiological Workstation
Starkey China
The Starkey Harmonia is an integrated audiological workstation combining pure tone audiometry, speech audiometry, tympanometry, and OAE testing in a single unified platform. It features a large 15-inch touchscreen display, modular transducer bay for quick instrument switching, and centralized patient data management with EMR integration. The workstation supports networked multi-room configurations for efficient clinical workflow.
Applications:

Phonak Infinio High-Frequency Audiometer
Phonak China
The Phonak Infinio is a specialized high-frequency audiometer capable of measuring hearing thresholds from 8000 Hz to 20,000 Hz, extending beyond the conventional audiometric range. It uses specialized high-frequency transducers and calibrated sound delivery for early detection of noise-induced hearing loss and ototoxicity. The device features frequency-specific threshold tracking with adaptive test procedures.
Applications:

Interacoustics AD629 Bone Conduction Audiometer
Interacoustics China
The Interacoustics AD629 is a dedicated bone conduction audiometer for assessing inner ear function by bypassing the outer and middle ear. It features calibrated bone vibrator output with mastoid and forehead placement options, frequency range from 250 Hz to 4000 Hz, and Weber and Rinne tuning fork test simulations. The device is essential for differentiating conductive from sensorineural hearing loss.
Applications:

Madsen Field Analyzer Pro
Madsen China
The Madsen Field Analyzer Pro is a professional field audiometer designed for sound field audiometry in acoustic laboratory environments. It features multi-channel speaker array control, calibrated sound field generation from 125 Hz to 8000 Hz, and free-field and diffuse-field test capabilities. The device supports aided and unaided testing conditions with real-time SPL monitoring at the patient position.
Applications:

Siemens Harmony Occupational Audiometer
Siemens China
The Siemens Harmony is a purpose-built occupational audiometer for workplace hearing conservation programs. It features automated OSHA and ISO standard compliance testing, efficient high-throughput screening protocols, noise exposure calculation with dosimetry integration, and employer reporting templates. The device supports serial audiometric testing with baseline and annual comparison analysis.
Applications:
Oticon SmartScreen School Screening Audiometer
Oticon China
The Oticon SmartScreen is a school-oriented screening audiometer designed for efficient large-scale hearing screening programs. It features simplified one-touch testing, automated pass/refer results per WHO criteria, instant color-coded reports, and batch student data management. The device includes ruggedized construction for high-traffic use and ambient noise indicators to ensure test environment validity.
Applications:

Starkey VetAud Veterinary Audiometer
Starkey China
The Starkey VetAud is a veterinary audiometer designed for hearing assessment in animals including dogs, cats, and laboratory species. It features species-specific frequency protocols from 125 Hz to 32,000 Hz, bone conduction testing for animals, and automated conditioned response recording. The device includes animal-friendly transducer designs and specialized software for veterinary hearing evaluation.
Applications:

Phonak ResearchLab Research Audiometer
Phonak China
The Phonak ResearchLab is a research-grade audiometer offering maximum flexibility for audiology research applications. It features programmable stimulus generation with arbitrary waveform output, precise timing control down to 1 microsecond, multi-channel recording capability, and open API for custom software integration. The device supports psychophysical paradigms including adaptive procedures, method of constant stimuli, and signal detection analysis.
Applications:

Interacoustics MobileScan Mobile Audiometer
Interacoustics China
The Interacoustics MobileScan is a tablet-based mobile audiometer designed for hearing assessment in remote and underserved areas. It connects to a smartphone or tablet via Bluetooth, uses calibrated audiometric headphones, and operates on rechargeable battery power for up to 12 hours. The device features cloud-based data storage, teleaudiology capabilities for remote specialist consultation, and offline testing mode with automatic data synchronization.
Applications:

Madsen Symphony Premium Audiological Suite
Madsen China
The Madsen Symphony Premium is an all-in-one premium audiological suite combining pure tone, speech, bone conduction, tympanometry, OAE, and ABR testing in a single luxurious workstation. It features dual 21.5-inch 4K displays, premium leather-covered patient response button, ambient chamber lighting control, and whisper-quiet cooling system. The suite includes concierge-level patient management with automated appointment scheduling and multi-language report generation.
Applications:
More in this Category
Explore other Diagnostic Equipment subcategories