Tonometers

Diagnostic Equipment

Tonometers(5 products)

Intraocular pressure measurement devices

CT-800 Computerized Non-Contact Tonometer
NMPA Class II, 国械注进20182160361

CT-800 Computerized Non-Contact Tonometer

CT-800 non-contact tonometer with gentle air puff, 8.5-inch color touch screen, built-in printer, IOL mode for pseudophakic eyes and manual CCT input for corrected IOP. Measurement range 1-30 mmHg / 1-60 mmHg.

Non-contact air-puff measurement8.5-inch touch screenBuilt-in printerIOL mode

Applications:

IOP screeningGlaucoma monitoringPre/post cataract evaluation
Inquire Now
NT-530 Non-Contact Tonometer
NMPA Class II, 国械注进20172166593

NT-530 Non-Contact Tonometer

NT-530 auto non-contact tonometer (with NT-510 in same registration) featuring 3D auto tracking, auto measurement, APC soft air control, tiltable 5.7-inch color LCD, and CCT-based IOP compensation for NT-530. Optional NT-530P also measures corneal thickness.

3D auto trackingAPC soft air controlTiltable 5.7-inch color LCDCCT compensation (NT-530)

Applications:

IOP measurementGlaucoma screeningPost-refractive surgery IOP
Inquire Now
7CR Auto Tonometer with Corneal Response Technology
NMPA Class II, 国械注进20152222275

7CR Auto Tonometer with Corneal Response Technology

7CR non-contact tonometer with patented Corneal Response Technology, providing both IOPg (Goldmann-correlated IOP) and IOPcc (corneal-compensated IOP) — valuable for normal-tension glaucoma, post-refractive surgery and biomechanically atypical corneas. Auto alignment, touch screen, built-in printer and confidence indicator.

Corneal Response TechnologyIOPg and IOPccAuto alignmentConfidence indicator

Applications:

Normal-tension glaucomaPost-refractive IOPCorneal biomechanics assessment
Inquire Now
HAAG-STREIT Goldmann Applanation Tonometer AT 900
NMPA Class II, 国械注进20142165507

HAAG-STREIT Goldmann Applanation Tonometer AT 900

The Goldmann applanation tonometer AT 900 — the clinical gold standard for IOP measurement since 1958. Models R, T and BQ mount on Haag-Streit and third-party slit lamps, reusable Goldmann prisms or disposable Tonosafe prisms. Measurement range 0-80 mmHg.

Goldmann applanation principleModels R / T / BQReusable or Tonosafe disposable prismsSwiss made

Applications:

Goldmann IOP measurementGlaucoma diagnosisSlit lamp integration
Inquire Now
ic100 (TA011) Handheld Rebound Tonometer
NMPA Class II, 国械注进20182160128

ic100 (TA011) Handheld Rebound Tonometer

Ic100 handheld rebound tonometer using patented induction-based rebound principle — no anesthesia or calibration required. Six short probe touches per reading, measurement range 7-50 mmHg, 230 g with batteries. Widely used for glaucoma screening.

Rebound technologyNo anesthesia needed7-50 mmHg range±1.2 mmHg accuracy (≤20 mmHg)

Applications:

Glaucoma screeningCommunity and outreach IOP checksPediatric and bedside measurement
Inquire Now